What Tabel 6 includes
BR18, bilag 2, Tabel 6 (Bygningsdele til beregning af klimapåvirkning) is the authority on scope under § 297, stk. 6. Building parts that Tabel 6 doesn’t mention are not included. Tabel 6 is published as an Excel file with eight categories, each split into types and building parts:
Each row also has a Detaljeringsniveau column, which states which material layers to include. A few rules from Tabel 6 come up often:
- Fasteners are excluded. Nails, screws, and wall ties don’t count. Structurally significant connections do.
- “Eventuelt som mængde råmateriale” means you may model the part as the quantity of its main raw materials. This is common for lifts and technical installations.
- Unfinished buildings (råhuse): parts needed for the building to function, such as flooring and paint, count even if they aren’t installed at completion.
Tabel 6 doesn’t use a classification system such as BIM7AA or CCS. It has its own categories. Real-Time LCA maps your classification codes onto them, as described below.
How Real-Time LCA uses your classification codes
Every element carries a classification code from your model. Real-Time LCA maps each code to a Tabel 6 category, which places the element in the right row of the BR18 report.Supported classification systems
Set the system and the parameter that holds the code under Settings → Classification. For Danish projects, the default system is BIMTypeCode, read from one of these parameters:BIMTypeCodeBIM7AACodeAssembly CodeKeynote
Assign codes that are missing
You can add codes in three ways:- In the authoring tool. Set the parameter in Revit, ArchiCAD, Rhino, or your IFC export, so the codes arrive with every publish. This is the most reliable option. See Revit, Rhino, or IFC requirements.
- In the Excel upload. Column A of the Excel template takes a classification code for each row.
- With AI Classification. Run AI Classification from Mapping tools. You can edit the Proposed code before you accept, so you can also use it to set codes by hand.
Why the BR18 report differs from the dashboard
The dashboard and the BR18 report count different things:
Both use the same reference area. So when the BR18 report total is lower than the dashboard, look for elements without a valid classification code.
1
Generate the BR18 report
Open Reports and generate LCA Documentation (Danish). See Reports.
2
Find the invalid codes
In the BR18 vejledning sheet, check the Ugyldige klassifikationskoder block. It lists the materials whose code couldn’t be matched.
3
Fix the codes
Correct the codes at the source or with AI Classification, then generate the report again.
Sources
- BR18, bilag 2, Tabel 6 (Excel file, version 5, 10 March 2025)
- Vejledning om bygningers klimapåvirkning (1 July 2025)
- SBi-anvisning 283, afsnit 2.2