> ## Documentation Index
> Fetch the complete documentation index at: https://docs.realtimelca.com/llms.txt
> Use this file to discover all available pages before exploring further.

# Quantities and units

> Where Real-Time LCA gets the quantities for Revit and Rhino models published through Speckle, how accurate they are, and how to get the best results.

When you sync a model, Real-Time LCA reads every element and works out how much of each material it contains: a volume, an area, a length, or a piece count. These quantities drive every emission figure in your project. This page explains where each number comes from, so you know which figures you can trust as-is and which ones to check.

This page covers models published with the Speckle v3 connectors for Revit and Rhino.

## Where the numbers come from

Real-Time LCA uses one of three sources for each element, in this order of preference:

| Source | What it means | Accuracy |
| - | - | - |
| **Revit's material takeoff** | Revit itself calculates the volume and area of every material inside an element, such as each layer of a wall. This is the same data you see in a Revit *Material Takeoff* schedule. | Exact. Matches what Revit reports. |
| **Element dimensions** | The element's own *Area*, *Volume*, *Length* or *Perimeter* parameters, or a width × height for windows and doors. | Exact for the element, but not split by material. |
| **Measured from geometry** | Real-Time LCA measures the 3D shape itself. This is used for elements Revit doesn't report quantities for, and for Rhino geometry where Rhino's own area and volume aren't available. | An approximation. See [Accuracy](#accuracy-what-to-expect). |

The tables below show which source applies to each Revit category and each Rhino geometry type.

## How quantities are combined in the Inventory

The **Inventory** on the **[Material Mapping](https://docs.realtimelca.com/user-guide/project/material-mapping.md)** page doesn't list every single element in your model. Instead, each entry in the Inventory combines all elements that share the same three characteristics:

1. **Category**, for example *Walls*
2. **Type**, for example *Exterior 300mm*
3. **Material**, for example *Concrete*

Their volumes, areas and lengths are added up into one total per entry.

For example, 40 walls of type *Exterior 300mm* each have a *Concrete* layer and a *Mineral wool* layer. The Inventory shows two entries: *Walls / Exterior 300mm / Concrete* with the combined concrete volume of all 40 walls, and *Walls / Exterior 300mm / Mineral wool* with the combined insulation volume.

The **pcs** (pieces) value tells you how many elements went into an entry. When you map an entry, you map every element in it at once.

Only these three characteristics decide the grouping. Elements that differ only in another property, such as their phase or a classification parameter, still end up in the same entry, and the entry shows that property from one of them.

> [!NOTE]
>
> If a layered element, such as a wall, floor, roof or ceiling, has two or more layers with the same material, those layers are combined into one entry for that material. For example, a wall with two *Gypsum board* layers shows one *Gypsum board* entry with the volume of both layers. This is how Revit's API reports material quantities, so Real-Time LCA can't split them back into separate layers. To keep layers apart, give each one its own material in Revit.

## Units

Every quantity is converted to metric before it reaches your project. You don't need to change your model's units.

| Quantity | Stored as | Model units accepted |
| - | - | - |
| Length | m | mm, cm, m, ft, in, plus Revit's English and German unit labels |
| Area | m² | mm², cm², m², ft², in², plus Revit's English and German unit labels |
| Volume | m³ | mm³, cm³, m³, ft³, in³, plus Revit's English and German unit labels |
| Count | pcs | Added automatically: the number of elements in each entry |
| Unrecognized unit | Dropped | The quantity is skipped rather than reported in the wrong unit |

## Revit

### Supported categories

Only elements in these categories are imported. Elements in any other category, such as **Furniture**, **Casework**, **Topography** or **Site**, are ignored.

| Group | Categories |
| - | - |
| Building envelope | Curtain Panels, Curtain Systems, Curtain Wall Mullions, Doors, Wall Sweeps, Walls, Windows |
| Floors and roofs | Ceilings, Fascias, Floors, Gutters, Roof Soffits, Roofs, Slab Edges |
| Circulation | Handrails, Landings, Railings, Ramps, Stairs, Supports (stringers and carriages), Top Rails |
| Structure | Columns, Structural Columns, Structural Connections, Structural Foundations, Structural Framing |
| Mechanical and plumbing | Air Terminals, Duct Accessories, Duct Fittings, Duct Insulation, Ducts, Fire Protection, Flex Ducts, Flex Pipes, Mechanical Equipment, MEP Networks, Pipe Accessories, Pipe Fittings, Pipe Insulation, Pipes, Plumbing Fixtures, Sprinklers |
| Electrical | Audio Visual Devices, Cable Tray Fittings, Cable Trays, Communication Devices, Conduit Fittings, Conduits, Data Devices, Electrical Equipment, Electrical Fixtures, Fire Alarm Devices, Lighting Devices, Lighting Fixtures, Nurse Call Devices, Security Devices, Telephone Devices, Wires |
| Other | Entourage, Food Service Equipment, Generic Models, Parts, Rooms, Specialty Equipment |

### How each category is quantified

Every supported category appears once in the tables below. "Material takeoff" means you get one entry per material, with the volume, area and (where Revit reports it) length of that material. Quantities in brackets, such as (m), arrive only when Revit provides them for that element.

If an element in a material-takeoff category reaches Real-Time LCA without a takeoff, see [When an element has no material information](#when-an-element-has-no-material-information).

**Building envelope**

| Category | Quantities | Source | Details |
| - | - | - | - |
| Curtain Panels | m³, m², (m), pcs | Material takeoff | One entry per material. |
| Curtain Systems | m³, m², (m), pcs | Material takeoff | One entry per material. |
| Curtain Wall Mullions | m³, m², (m), pcs | Material takeoff | One entry per material. |
| Doors | m², plus material entries when available, pcs | Geometry or element dimensions | Always adds a *Total Area of Doors* entry with the opening area, plus the material takeoff when available. See [Windows and doors](#windows-and-doors). |
| Wall Sweeps | m³, m², (m), pcs | Material takeoff | One entry per material. |
| Walls | m³, m², m, pcs | Material takeoff | One entry per layer material. Layers that share a material are combined into one entry. The wall's length is added to every entry. |
| Windows | m², plus material entries when available, pcs | Geometry or element dimensions | Always adds a *Total Area of Windows* entry with the opening area. Revit's material takeoff for frame and glass is added on top when Revit provides it. See [Windows and doors](#windows-and-doors). |

**Floors and roofs**

| Category | Quantities | Source | Details |
| - | - | - | - |
| Ceilings | m³, m², (m), pcs | Material takeoff | One entry per layer material. Layers that share a material are combined into one entry. |
| Fascias | m³, m², (m), pcs | Material takeoff | One entry per material. |
| Floors | m³, m², (m), pcs | Material takeoff | One entry per layer material. Layers that share a material are combined into one entry. |
| Gutters | m³, m², (m), pcs | Material takeoff | One entry per material. |
| Roof Soffits | m³, m², (m), pcs | Material takeoff | One entry per layer material. Layers that share a material are combined into one entry. |
| Roofs | m³, m², (m), pcs | Material takeoff | One entry per layer material. Layers that share a material are combined into one entry. |
| Slab Edges | m³, m², (m), pcs | Material takeoff | One entry per material. |

**Circulation**

| Category | Quantities | Source | Details |
| - | - | - | - |
| Handrails | m³, m², m, pcs | Geometry | Measured like railings. |
| Landings | m³, m², (m), pcs | Material takeoff | One entry per material. |
| Railings | m³, m², m, pcs | Geometry | Revit doesn't report quantities for balusters and rails, so the shape is measured. You get one entry per render material. The railing length is added to each entry. |
| Ramps | m³, m², pcs | Geometry | Always measured from the shape: total volume plus the area of the largest flat face. The material name comes from the element's render material. |
| Stairs | m³, m², (m), pcs | Material takeoff | One entry per material. |
| Supports (stringers and carriages) | m³, m², (m), pcs | Material takeoff | One entry per material. |
| Top Rails | m³, m², m, pcs | Geometry | Measured like railings. |

**Structure**

| Category | Quantities | Source | Details |
| - | - | - | - |
| Columns (architectural) | m³, m², m, pcs | Material takeoff + geometry | Length includes extensions. If Revit has no length, the longest edge of the column's shape is used. |
| Structural Columns | m³, m², (m), pcs | Material takeoff | One entry per material. |
| Structural Connections | m³, m², (m), pcs | Material takeoff | One entry per material. |
| Structural Foundations | m³, m², (m), pcs | Material takeoff | One entry per material. |
| Structural Framing (beams) | m³, m², m, pcs | Material takeoff + element dimensions | Length includes start and end extensions. If Revit has no length, the beam's centerline is measured. |

**Mechanical and plumbing**

| Category | Quantities | Source | Details |
| - | - | - | - |
| Air Terminals | m³, m², (m), pcs | Material takeoff | One entry per material. |
| Duct Accessories | m³, m², (m), pcs | Material takeoff | One entry per material. |
| Duct Fittings | m³, m², (m), pcs | Material takeoff | One entry per material. |
| Duct Insulation | m³, m², (m), pcs | Material takeoff | One entry per material. |
| Ducts | m³, m², (m), pcs | Material takeoff | The duct size is added to the type name, so each size becomes its own entry. |
| Fire Protection | m³, m², (m), pcs | Material takeoff | One entry per material. |
| Flex Ducts | m³, m², (m), pcs | Material takeoff | One entry per material. |
| Flex Pipes | m³, m², (m), pcs | Material takeoff | One entry per material. |
| Mechanical Equipment | m³, m², (m), pcs | Material takeoff | One entry per material. |
| MEP Networks | pcs | None | Counted only. Area and volume are 0. |
| Pipe Accessories | m³, m², (m), pcs | Material takeoff | One entry per material. |
| Pipe Fittings | m³, m², (m), pcs | Material takeoff | One entry per material. |
| Pipe Insulation | m³, m², (m), pcs | Material takeoff | One entry per material. |
| Pipes | m³, m², (m), pcs | Material takeoff | The pipe size is added to the type name, so each size becomes its own entry. |
| Plumbing Fixtures | m³, m², (m), pcs | Material takeoff | One entry per material. |
| Sprinklers | m³, m², (m), pcs | Material takeoff | One entry per material. |

**Electrical**

| Category | Quantities | Source | Details |
| - | - | - | - |
| Audio Visual Devices | m³, m², (m), pcs | Material takeoff | One entry per material. |
| Cable Tray Fittings | m³, m², (m), pcs | Material takeoff | One entry per material. |
| Cable Trays | m³, m², (m), pcs | Material takeoff | One entry per material. |
| Communication Devices | m³, m², (m), pcs | Material takeoff | One entry per material. |
| Conduit Fittings | m³, m², (m), pcs | Material takeoff | One entry per material. |
| Conduits | m³, m², (m), pcs | Material takeoff | The conduit size is added to the type name. |
| Data Devices | m³, m², (m), pcs | Material takeoff | One entry per material. |
| Electrical Equipment | m³, m², (m), pcs | Material takeoff | One entry per material. |
| Electrical Fixtures | m³, m², (m), pcs | Material takeoff | One entry per material. |
| Fire Alarm Devices | m³, m², (m), pcs | Material takeoff | One entry per material. |
| Lighting Devices | m³, m², (m), pcs | Material takeoff | One entry per material. |
| Lighting Fixtures | m³, m², (m), pcs | Material takeoff | One entry per material. |
| Nurse Call Devices | m³, m², (m), pcs | Material takeoff | One entry per material. |
| Security Devices | m³, m², (m), pcs | Material takeoff | One entry per material. |
| Telephone Devices | m³, m², (m), pcs | Material takeoff | One entry per material. |
| Wires | m³, m², (m), pcs | Material takeoff | The wire size is added to the type name. |

**Other**

| Category | Quantities | Source | Details |
| - | - | - | - |
| Entourage | m³, m², (m), pcs | Material takeoff | One entry per material. |
| Food Service Equipment | m³, m², (m), pcs | Material takeoff | One entry per material. |
| Generic Models | m³, m², pcs | Geometry | Always measured from the shape: total volume plus the area of the largest flat face. The material name comes from the element's render material. |
| Parts | Same as the original element, pcs | Material takeoff | Reported under the original element's category and type. |
| Rooms | m², m, pcs | Element dimensions | Creates *Floor Finish*, *Base Finish* and *Ceiling Finish* entries from the room's finish parameters, each with the room's area and perimeter. Only finishes that are filled in are imported. |
| Specialty Equipment | m³, m², (m), pcs | Material takeoff | One entry per material. |

### Windows and doors

Windows and doors are usually modeled as families with many small parts, so Real-Time LCA adds one extra entry per window or door type that holds the opening area in m². In **Material Mapping** you find it under the window's or door's category and type, with the material name:

* **Total Area of Windows** for elements in the Windows category
* **Total Area of Doors** for elements in the Doors category

Map this entry to a product whose EPD is declared per m², such as a complete window or door unit. Any frame and glass materials that Revit reports appear as separate entries next to it, so make sure you don't count the same window twice.

The opening area is worked out as:

1. The area of the largest face of the window's or door's bounding box. This is the box that fully encloses the element's shape.
2. If there's no shape, the family's width × height parameters, from the type first and then the instance.

The bounding box works well for rectangular windows and doors. For round, arched or angled openings, the box is larger than the opening itself, so the area is overestimated.

### When an element has no material information

Some elements reach Real-Time LCA without Revit's material takeoff. This happens with some families and categories, or when no material is assigned in Revit. Real-Time LCA then tries, in order:

| Step | Applies to | What you get |
| - | - | - |
| 1. Opening area | Windows, Doors | One *Total Area of Windows* or *Total Area of Doors* entry, as described above. |
| 2. Render material and shape | Railings, Ramps, Generic Models | Quantities measured from the shape, named after the element's render material (its appearance in Revit). |
| 3. Element dimensions | Everything else | One entry with material **Unknown**, carrying the element's area, volume, length and perimeter. |

Layers or parts that have no material assigned in Revit also arrive as **Unknown**.

> [!TIP]
>
> **Unknown** entries still carry correct quantities, but you need to map them to a material by hand. To avoid them, assign a material to every layer and family in Revit before you publish.

## Rhino

### How geometry is quantified

Rhino has no material takeoff, but the Speckle connector usually sends an **area** and a **volume** with each piece of geometry, as calculated by Rhino. Real-Time LCA uses those values first and only measures the shape itself where they're missing or zero:

| Geometry | Quantities | Volume | Area |
| - | - | - | - |
| Closed solid, polysurface or mesh | m³, m², pcs | The volume Rhino reports. | Replaced by the area of the largest flat face, measured from the shape. |
| Open surface, polysurface or mesh | m², pcs | 0 | The surface area Rhino reports. |
| Geometry that arrives with area and volume both 0 | m³, m², pcs | Measured from the shape. | Total surface area, measured from the shape. |
| Block instance | m³, m², pcs | Moved into place, then handled like the geometry it contains. | Same as the geometry it contains. |
| Curves, lines, polylines | Coming soon: m, pcs | Not quantified yet. | Not quantified yet. |
| Points | Coming soon: pcs | Not quantified yet. | Not quantified yet. |

If Speckle also sends a length, it's passed through as m.

> [!NOTE]
>
> Curves, lines, polylines and points aren't quantified yet. Until they are, they don't appear in **Material Mapping**.

### How objects are combined in the Inventory

As described in [How quantities are combined in the Inventory](#how-quantities-are-combined-in-the-inventory), the Inventory groups elements by **Category**, **Type** and **Material**. Rhino works the same way, but Rhino objects have no category or type, so Real-Time LCA derives all three from your layers and render materials:

| Inventory field | Comes from |
| - | - |
| Category | The name of the layer the object is on |
| Type | *Generic* followed by the layer name, for example *Generic Facade* |
| Material | The render material of the object or its layer, or **Unknown** if there isn't one |
| Classification | The `BIMTypeCode` user text, if set. Not used for grouping. |

Because the type is built from the layer name, the grouping in practice comes down to **layer + render material**:

* All objects on the same layer with the same render material become **one entry**. Their volumes and areas are added together.
* Objects on the same layer with **different** render materials become **separate entries**, one per material.
* Objects with the same render material on **different** layers also stay **separate**.

For example, a layer *Facade* holds 120 panels with the render material *Aluminium* and 30 panels with *Glass*. The Inventory shows two entries: *Facade / Generic Facade / Aluminium* and *Facade / Generic Facade / Glass*.

**pcs** counts the pieces of geometry in an entry, not the Rhino objects. Each object is measured per display mesh, so an object made of several separate meshes can count as more than one piece.

> [!TIP]
>
> To control how your Rhino model appears in the Inventory, put each building part on its own layer and give it a meaningful render material. To split something into its own entry, move it to its own layer.

## Accuracy: what to expect

### Strengths

* **Revit quantities match Revit.** Wherever Revit's material takeoff is available, which covers most walls, floors, roofs, ceilings, structure and MEP elements, the volumes and areas are the ones Revit calculates. They're not re-estimated.
* **Layers are split automatically.** A layered wall, floor or roof becomes one entry per material, so concrete, insulation and cladding can each get their own EPD. Layers that share a material are combined.
* **Broad coverage.** Envelope, structure, circulation and most MEP categories are imported without any setup.
* **Units are handled for you.** Imperial and metric models, and English and German Revit, are converted to metric automatically.

### Limitations

* **Geometry-based quantities are approximations.** Railings, ramps, generic models and window and door openings are measured from the 3D shape. So is the area of closed Rhino solids. The area of a measured element is its **largest flat face**, not its total surface. This suits panels and slabs, but understates the area of curved or folded shapes.
* **Windows and doors come in as one opening area.** Unless Revit provides a material takeoff for the family, you get the opening area, not a split into frame and glass. Non-rectangular openings are overestimated.
* **Some categories aren't imported.** Furniture, casework, site and topography elements, and anything not in the [supported list](#supported-categories), don't appear in your project.
* **Missing materials become Unknown.** Elements without a material in Revit or a render material in Rhino need manual mapping.
* **Rhino depends on clean geometry.** Only closed solids give a volume. Open or broken geometry gives a volume of 0. Overlapping solids are counted twice.

> [!WARNING]
>
> For geometry-based quantities, compare a few totals against your model before you rely on the results for reporting. This matters most for irregular shapes, non-rectangular openings and Rhino models.

### Getting the most accurate results

* **In Revit:** assign a material to every layer of walls, floors and roofs, and to every family. Prefer system families, such as walls, floors and stairs, over generic models where possible, because they come with Revit's exact takeoff.
* **In Rhino:** model building parts as closed solids, put each building part on its own layer, and assign render materials by layer or object.


This documentation is built and hosted on [Mintlify](https://mintlify.com), a developer documentation platform.