# Reference area

> How BR18 (2025) defines the referenceareal and the heated floor area, and how to enter both in Real-Time LCA.

A BR18 result is reported per m² per year, so the area you divide by matters as much as the emissions. BR18 (2025) uses two different areas:

| Area | Danish term | Used for |
| - | - | - |
| Reference area | *referenceareal* (§ 297, stk. 5) | A1–A3, A4, A5, B4, C3, C4 and D |
| Heated floor area | *opvarmet etageareal* (§ 256) | B6 operational energy |

Mixing the two up is one of the most common errors in a Danish climate calculation. Check both before you issue a report.

## How BR18 defines the reference area

The reference area starts from the gross floor area (*etageareal*) under § 455, then applies seven modifications from § 297, stk. 5:

| Area | Counts as | BR18 wording |
| - | - | - |
| All basements, waste rooms at ground level, and shelters (*sikringsrum*) | 100 % | *Alle kælderarealer, affaldsrum i terrænniveau og sikringsrum medregnes.* |
| Conservatories, enclosed balconies, and similar | 50 % | *Udestuer, altanlukninger og lignende* |
| Integrated garages for single-family houses, terraced houses, and similar | 50 % | *Integrerede garager til enfamiliehuse, rækkehuse og lignende* |
| External ramps, stairs, fire escapes, balconies, and access balconies | 25 % | *Udvendige ramper, trapper, brandtrapper, altaner, altangange og lignende* |
| Integrated carports, sheds, canopies, and similar | 25 % | *Integrerede carporte, udhuse, overdækninger, skure og lignende* |
| Walk-on ceilings and similar | 25 % | *Walk-on-ceilings og lignende* |
| Covered, non-integrated terraces and used roof surfaces | 0 % | *Overdækkede, ikke-integrerede terrasser, samt udnyttede tagflader og lignende, medtages ikke.* |

Basements count in full whether they are heated or not. Freestanding shelters and waste rooms are not part of the building and don't count.

### Areas are weighted, materials are not

A weighting reduces the *area* only. The materials in a carport that counts at 25 % still count at 100 % in the calculation.

The exception is the 0 % row. Covered, non-integrated terraces and used roof surfaces are left out of both the area and the material take-off.

> [!TIP]
>
> SBi-anvisning 283, afsnit 2.1, works through borderline cases such as basement parking, parking under a building on columns, roof plant rooms, and covered courtyards. When a case is genuinely unclear, agree it with the municipality (*myndighedsdialog*) rather than deciding it alone.

## How BR18 defines the heated floor area

B6 is divided by the heated floor area under § 256, not by the reference area. That area comes from the building's energy frame calculation (*energirammeberegning*).

The installation standard values in Tabel 7 use a third basis: the total heated floor area **plus** the heated basement area. See [Environmental data and lifetimes](https://docs.realtimelca.com/methodology-and-compliance/national-compliance/denmark/environmental-data-and-lifetimes.md#installation-standard-values).

## Enter the areas in Real-Time LCA

Open the project's **Settings** and go to [Building area](https://docs.realtimelca.com/user-guide/project/project-settings.md#building-area).

**1. Enter the gross areas**

Enter the gross area **above ground** and **below ground**. Both count in full, which matches the 100 % rule for basements. Include ground-level waste rooms and integrated shelters in the above-ground figure.

**2. Enter the heated areas**

Enter how much of each gross area is heated. Real-Time LCA divides B6 by the heated area above and below ground. See [Operational energy (B6)](https://docs.realtimelca.com/methodology-and-compliance/national-compliance/denmark/operational-energy.md).

**3. Add the weighted areas**

Add one row for each weighted area, choose its type, and enter the area before weighting. Real-Time LCA applies the multiplier:

| Type in Real-Time LCA | Multiplier |
| - | - |
| Conservatories, balcony enclosures and similar | 0.50 |
| Integrated garages for single-family houses, row houses and similar | 0.50 |
| External ramps, stairs, fire escapes, balconies, balcony corridors and similar | 0.25 |
| Integrated carports, sheds, canopies, outbuildings and similar | 0.25 |
| Walk-on ceilings and similar | 0.25 |

Don't add covered, non-integrated terraces or used roof surfaces. They count at 0 %.

The reference area is then:

> gross area above ground + gross area below ground + Σ (weighted area × multiplier)

### Same area on the dashboard and in the report

The dashboard and the BR18 Excel report use the same reference area. If the two totals differ, the cause is almost always classification, not area. See [Building parts and classification](https://docs.realtimelca.com/methodology-and-compliance/national-compliance/denmark/building-parts-and-classification.md#why-the-br18-report-differs-from-the-dashboard).

## Mixed-use buildings

For a building with several uses, BR18 § 298 sets the limit value as an area-weighted average of each use's limit. Shared areas that serve housing, such as a common kitchen in a care home, count as housing.

In Real-Time LCA, add one building type per use under **Building area**. See [Mixed-use buildings](https://docs.realtimelca.com/user-guide/project/project-settings.md#mixed-use-buildings).

## Sources

* [BR18 § 297–298](https://www.bygningsreglementet.dk/tekniske-bestemmelser/11/krav/297_298/) on bygningsreglementet.dk
* [Vejledning om bygningers klimapåvirkning (1 July 2025)](https://www.bygningsreglementet.dk/tekniske-bestemmelser/11/brv/bygningers-klimapaavirkning-1-juli-2025/)
* SBi-anvisning 283, *Beregning af bygningers klimapåvirkning – BR18, version 2025*, afsnit 2.1 and Bilag 5