# Building parts and classification

> Which building parts BR18 Tabel 6 includes, how Real-Time LCA uses classification codes to find them, and why the BR18 report can differ from the dashboard.

BR18 decides which parts of a building enter the climate calculation. Real-Time LCA decides which of *your* elements are those parts by reading their classification code. When a code is missing or wrong, an element drops out of the BR18 report even though it's mapped.

## What Tabel 6 includes

BR18, bilag 2, **Tabel 6** (*Bygningsdele til beregning af klimapåvirkning*) is the authority on scope under § 297, stk. 6. Building parts that Tabel 6 doesn't mention are not included.

Tabel 6 is published as an Excel file with eight categories, each split into types and building parts:

| Category | What's included |
| - | - |
| Bygningsbasis | Foundations, ground slabs, and other building-base parts |
| Primære bygningsdele | Load-bearing and enclosing parts: walls, decks, roofs, columns, and beams |
| Kompletterende bygningsdele | Windows, doors, stairs, balconies, internal walls, and similar |
| Overfladebygningsdele | Floor, wall, and ceiling finishes |
| VVS-anlæg | Plumbing, heating, ventilation, and cooling. Only straight runs of pipes and ducts count, not bends. |
| El- og mekaniske anlæg | Only solar PV installations (and their racks), lifts, and escalators. Other electrical installations are excluded. |
| Inventar og teknisk udstyr | Nothing. Fixed and loose furniture and equipment are excluded. |
| Beplantning og belægning | Paving only where it's inside the [reference area](https://docs.realtimelca.com/methodology-and-compliance/national-compliance/denmark/reference-area.md). Planting itself is excluded. |

Each row also has a **Detaljeringsniveau** column, which states which material layers to include. A few rules from Tabel 6 come up often:

* **Fasteners are excluded.** Nails, screws, and wall ties don't count. Structurally significant connections do.
* **"Eventuelt som mængde råmateriale"** means you may model the part as the quantity of its main raw materials. This is common for lifts and technical installations.
* **Unfinished buildings (*råhuse*)**: parts needed for the building to function, such as flooring and paint, count even if they aren't installed at completion.

> [!NOTE]
>
> Tabel 6 doesn't use a classification system such as BIM7AA or CCS. It has its own categories. Real-Time LCA maps your classification codes onto them, as described below.

## How Real-Time LCA uses your classification codes

Every element carries a classification code from your model. Real-Time LCA maps each code to a Tabel 6 category, which places the element in the right row of the BR18 report.

### Supported classification systems

Set the system and the parameter that holds the code under [Settings → Classification](https://docs.realtimelca.com/user-guide/project/project-settings.md#classification). For Danish projects, the default system is **BIMTypeCode**, read from one of these parameters:

* `BIMTypeCode`
* `BIM7AACode`
* `Assembly Code`
* `Keynote`

CCS and CCI codes are also supported. NES codes are not supported.

### Assign codes that are missing

You can add codes in three ways:

1. **In the authoring tool.** Set the parameter in Revit, ArchiCAD, Rhino, or your IFC export, so the codes arrive with every publish. This is the most reliable option. See [Revit](https://docs.realtimelca.com/user-guide/integrations/speckle/revit.md), [Rhino](https://docs.realtimelca.com/user-guide/integrations/speckle/rhino.md), or [IFC requirements](https://docs.realtimelca.com/user-guide/integrations/ifc-file-upload/requirements.md#classification).
2. **In the Excel upload.** Column A of the [Excel template](https://docs.realtimelca.com/user-guide/integrations/excel-file-upload.md) takes a classification code for each row.
3. **With AI Classification.** Run [AI Classification](https://docs.realtimelca.com/user-guide/integrations/ai-tools/ai-classification.md) from **Mapping tools**. You can edit the **Proposed code** before you accept, so you can also use it to set codes by hand.

## Why the BR18 report differs from the dashboard

The dashboard and the BR18 report count different things:

| | Dashboard | BR18 Excel report |
| - | - | - |
| Which elements count | Every mapped element that's included in the calculation | Only elements whose classification code maps to a Tabel 6 category |
| Elements with a missing or unknown code | Counted | Listed under **Ugyldige klassifikationskoder** and left out of the totals |

Both use the same reference area. So when the BR18 report total is lower than the dashboard, look for elements without a valid classification code.

**1. Generate the BR18 report**

Open **Reports** and generate **LCA Documentation (Danish)**. See [Reports](https://docs.realtimelca.com/user-guide/project/reports.md).

**2. Find the invalid codes**

In the **BR18 vejledning** sheet, check the **Ugyldige klassifikationskoder** block. It lists the materials whose code couldn't be matched.

**3. Fix the codes**

Correct the codes at the source or with AI Classification, then generate the report again.

In the same sheet, rows shaded grey are Tabel 6 rows that aren't part of the calculation for the project's calculation type.

## Sources

* [BR18, bilag 2, Tabel 6](https://www.bygningsreglementet.dk/bilag/b2/bilag_2/) (Excel file, version 5, 10 March 2025)